MI Series Inverter
-
Foreword
Dear user, thank you very much for using the MI series photovoltaic off-grid inverter products developed and manufactured by Zhenyuan Electric Co., Ltd. We sincerely hope that this product can meet your needs, and we hope that you can make valuable suggestions on the performance and functions of the product Comments and suggestions, we will continue to improve to provide better products and solutions.
Please read this manual carefully before using this product. Please keep this manual in a safe place for the convenience of related personnel.
Product whole introduction
Figure 1 Inverter working system
I series single-phase off-grid inverter pure sine wave output, power frequency transformer isolation, strong shock resistance and excellent overload performance, suitable for air conditioning, television, radio, refrigerator, washing machine, computer, power tool, lighting, industrial equipment, telecommunications Equipment and other loads.
Working mode
Mode
Comment
Switching
AC Charge priority
When there is AC input power, the utility power supplies power to the load; when there is no AC input power, the load is powered by the battery inverter
≤5ms
Bat. priority
When the battery has power, the battery will invert to supply the load; when there is no battery or the battery is under voltage, the load will be supplied by the AC power.
≤5ms
Table 1 I series inverter working mode table
Appearance description
The appearance of MI1000/MI2000/MI3000 inverter is shown in Figure 7. The surface of the machine mainly includes touch screen, indicator light, input/output interface, etc.
Figure 7 MI1000/MI2000/MI3000 appearance drawings
Position
description
Remark
1
12V/5VDC output
12V maximum continuous output 1A current; 5V maximum output 2A current
2
LCD operation interface
3
BX-801 AC socket
Maximum current 10A
4
Battery input switch
Make sure the switch is off during installation
5
AC Input switch
National standard product interface; 15A fuse
6
Battery input terminal
120A Anderson Terminal
7
MC4 connect terminal
Photovoltaic connection terminals, the current on a single group of terminals cannot exceed 15A
Table 2 MI1000/MI2000/MI3000 input and output interface list
The appearance of MI4000/MI5000 inverter is shown in Figure 8. The surface of the machine mainly includes touch screen, indicator light, input/output interface, etc.
Figure 8 MI4000/MI5000 appearance drawings
Position
description
Remark
1
12V/5VDC output
12V maximum continuous output 1A current; 5V maximum output 2A current
2
LCD operation interface
3
BX-801 AC socket
Max. Current 10A
4
AC Input switch
Make sure the switch is off during installation
5
Battery input switch
Make sure the switch is off during installation
6
ACInput connection terminal
L is the live line, N is the neutral line, and PE is the ground line. Both are M4 connectors
7
ACOutput connection terminal
L is the live line, N is the neutral line, and PE is the ground line. Both are M4 connectors
8
Battery input terminal
Both are M8 connectors
9
MC4Connection terminal
PV connection terminals, the current on a single group of terminals cannot exceed 15A
Table 3 MI4000/MI5000 input and output interface list